Hitachi Frekvensomformer X200

Varenummer: X200-0xx-SFEF
Producentens varenr.: X200
DKK 0,00 inkl. moms

X200

The economic drive solution for applications up to 7.5 kW. The X200 frequency inverters are suitable for pump and fan applications as well as for common tasks in machine construction. With the integrated EMC filter the inverter fullfills EN61800-3 standard and is complying with standards like CE, UL, cUL, c-Tick and RoHS.

  • 0.2 ~ 7.5 kW
  • Integrated EMC Filter
  • Automatic Energy saving function
  • RS485 Interface with Modbus RTU on board
  • Network Options: Profibus, CanOpen
  • RoHS Compliance
  • Side-by-Side installation
  • Global standards CE, UL, c-UL und c-Tick
X2001- / 3-phase 200 V class 
Model number002 SFEF004 SFEF005 SFEF007 SFEF011 SFEF015 SFEF022 SFEF 
Applicable motor (kW)0.20.40.550.71.11.52.2 
Rated output current (A)1.42.63.04.05.07.110.0 
Rated input voltage1 ~ 200 … 240 V, +10 %, -15 %, 50/60 Hz ±5 % 
Rated output voltage3 ~ 200 … 240 V (corresponding to input voltage) 
Integrated EMC filterEN61800-3 category C1 filter 
Output frequency range0.5 … 400 Hz 
Frequency accuracy (at 25 °C ±10 °C)Analogue setting: ±0.4 %, digital setting: ±0.01 % 
Frequency setting resolutionAnalogue setting: Maximum frequency/1000, digital setting: 0.1 Hz 
V/f characteristicsV/f control, V/f variable (constant torque, reduced torque) 
Overload capacity150 % for 60 s 
Acceleration/deceleration time0.01 - 3000 s (linear, sigmoid), two stage accel./decel. 
Starting torque100 % at 6 Hz 
InputIntelligent input terminal10 kOhm input impedance, sink / source logic selectable 
FunctionsFW(Forward), RV(Reverse), CF1-CF4(Multispeed command), JG(Jogging), DB(External DC braking), SET(Second motor constants setting), 2CH(Second accel./decel.), FRS(Free-run stop), EXT(External trip), USP(Unattended start protection), SFT(Software lock), AT(Analog input selection), RS(Reset), PTC(Thermistor input), STA(3-wire start), STP(3-wire stop), F/R(3-wire fwd./rev.), PID(PID On/Off), PIDC(PID reset), UP/DWN(Remote-controlled accel./decel.) , UDC(Remote-controlled data clearing), OPE(Operator control), ADD(ADD frequency enable), F-TM(force terminal mode), RDY(quick start enable),S-ST(Special-Set 2nd Motor Data),EMR, NO(Not selected) 
OutputIntelligent output terminal27V DC 50mA max open collector output, 1 terminals, 1c output 250V AC/30V DC 2.5A relay (AL0, AL1, AL2 terminals) 
FunctionsRUN(run signal), FA1(Frequency arrival type 1 - constant speed), FA2(Frequency arrival type 2 - over-frequency), OL(overload advance notice signal), OD(Output deviation for PID control), AL(alarm signal), DC(Wire brake detect on analog input), FBV(PID Second Stage Output), NDC(ModBus Network Detection Signal), LOG(Logic Output Function), ODC(Option Card Detection Signal), LOC(Low load) 
Analogue output terminal0 … 10 V, analogue frequency monitor, analogue current monitor 
Serial portRS485 (Modbus RTU) 
StandardsCE, UL, cUL, c-Tick 
ProtectionOvercurrent, overvoltage, undervoltage, overload, overheat, ground fault protection at startup, input overvoltage, external trip, EEPROM error, CPU error, USP error, Termistor error, Driver error, Safety stop 
Environ-mental conditionsTemperature / humidity-10 … +50 °C (carrier derating required for ambient temperature higher than 40 °C), no freezing / 20 … 90 % humidity (non condensing) 
Vibration / lnstallation5.9 m/s2 10…55 Hz / altitude 1000 m or less, indoors, no corrosive gases or dust 
OptionsRemote operator, copy unit, cable for digital operator, reactor for improving power factor, noise filter, ProDrive Software 
Protection classIP20 
Weight kg (approx.)0.81.01.52.42.51.52.3 
 80 x 155 x 9380 x 155 x 107110 x 189 x 128110 x 189 x 155
 
 
X2003-phase 400 V class
Model number004 HFEF007 HFEF015 HFEF022 HFEF030 HFEF040 HFEF055 HFEF075 HFEF
Applicable motor (kW)0.40.71.52.23.04.05.57.5
Rated output current (A)1.52.53.85.57.88.61316
Rated input voltage3 ~ 380 … 480 V, +10 %, -15 %, 50/60 Hz ±5 %
Rated output voltage3 ~ 380 … 480 V (corresponding to input voltage)
Integrated EMC filterEN61800-3 category C2 filter
Output frequency range0.5 … 400 Hz
Frequency accuracy (at 25 °C ±10 °C)Analogue setting: ±0.4 %, digital setting: ±0.01 %
Frequency setting resolutionAnalogue setting: Maximum frequency/1000, digital setting: 0.1 Hz
V/f characteristicsV/f control, V/f variable (constant torque, reduced torque)
Overload capacity150 % for 60 s
Acceleration/deceleration time0.01 - 3000 s (linear, sigmoid), two stage accel./decel.
Starting torque100 % at 6 Hz
InputIntelligent input terminal10 kOhm input impedance, sink / source logic selectable
FunctionsFW(Forward), RV(Reverse), CF1-CF4(Multispeed command), JG(Jogging), DB(External DC braking), SET(Second motor constants setting), 2CH(Second accel./decel.), FRS(Free-run stop), EXT(External trip), USP(Unattended start protection), SFT(Software lock), AT(Analog input selection), RS(Reset), PTC(Thermistor input), STA(3-wire start), STP(3-wire stop), F/R(3-wire fwd./rev.), PID(PID On/Off), PIDC(PID reset), UP/DWN(Remote-controlled accel./decel.) , UDC(Remote-controlled data clearing), OPE(Operator control), ADD(ADD frequency enable), F-TM(force terminal mode), RDY(quick start enable),S-ST(Special-Set 2nd Motor Data),EMR(Safety stop), NO(Not selected)
OutputIntelligent output terminal27V DC 50mA max open collector output, 1 terminals, 1c output 250V AC/30V DC 2.5A relay (AL0, AL1, AL2 terminals)
FunctionsRUN(run signal), FA1(Frequency arrival type 1 - constant speed), FA2(Frequency arrival type 2 - over-frequency), OL(overload advance notice signal), OD(Output deviation for PID control), AL(alarm signal), DC(Wire brake detect on analog input), FBV(PID Second Stage Output), NDC(ModBus Network Detection Signal), LOG(Logic Output Function), ODC(Option Card Detection Signal), LOC(Low load)
Analogue output terminal0 … 10 V, analogue frequency monitor, analogue current monitor
Serial portRS485 (Modbus RTU)
StandardsCE, UL, cUL, c-Tick
ProtectionOvercurrent, overvoltage, undervoltage, overload, overheat, ground fault protection at startup, input overvoltage, external trip, EEPROM error, CPU error, USP error, Termistor error, Driver error, Safety stop
Environ-mental conditionsTemperature / humidity-10 … +50 °C (carrier derating required for ambient temperature higher than 40 °C), no freezing / 20 … 90 % humidity (non condensing)
Vibration / lnstallation5.9 m/s2 10…55 Hz / altitude 1000 m or less, indoors, no corrosive gases or dust
OptionsRemote operator, copy unit, cable for digital operator, reactor for improving power factor, noise filter, ProDrive Software
Protection classIP20
Weight kg (approx.)1.52.32.45.55.7
Dimensions W/H/D in mm110 x 189 x 128110 x 189 x 155180 x 250 x 163
          * Item specifications are preliminary and are subject to change without notice   
 
*
*
*
*
Produkt detaljer

X200

The economic drive solution for applications up to 7.5 kW. The X200 frequency inverters are suitable for pump and fan applications as well as for common tasks in machine construction. With the integrated EMC filter the inverter fullfills EN61800-3 standard and is complying with standards like CE, UL, cUL, c-Tick and RoHS.

  • 0.2 ~ 7.5 kW
  • Integrated EMC Filter
  • Automatic Energy saving function
  • RS485 Interface with Modbus RTU on board
  • Network Options: Profibus, CanOpen
  • RoHS Compliance
  • Side-by-Side installation
  • Global standards CE, UL, c-UL und c-Tick
X2001- / 3-phase 200 V class 
Model number002 SFEF004 SFEF005 SFEF007 SFEF011 SFEF015 SFEF022 SFEF 
Applicable motor (kW)0.20.40.550.71.11.52.2 
Rated output current (A)1.42.63.04.05.07.110.0 
Rated input voltage1 ~ 200 … 240 V, +10 %, -15 %, 50/60 Hz ±5 % 
Rated output voltage3 ~ 200 … 240 V (corresponding to input voltage) 
Integrated EMC filterEN61800-3 category C1 filter 
Output frequency range0.5 … 400 Hz 
Frequency accuracy (at 25 °C ±10 °C)Analogue setting: ±0.4 %, digital setting: ±0.01 % 
Frequency setting resolutionAnalogue setting: Maximum frequency/1000, digital setting: 0.1 Hz 
V/f characteristicsV/f control, V/f variable (constant torque, reduced torque) 
Overload capacity150 % for 60 s 
Acceleration/deceleration time0.01 - 3000 s (linear, sigmoid), two stage accel./decel. 
Starting torque100 % at 6 Hz 
InputIntelligent input terminal10 kOhm input impedance, sink / source logic selectable 
FunctionsFW(Forward), RV(Reverse), CF1-CF4(Multispeed command), JG(Jogging), DB(External DC braking), SET(Second motor constants setting), 2CH(Second accel./decel.), FRS(Free-run stop), EXT(External trip), USP(Unattended start protection), SFT(Software lock), AT(Analog input selection), RS(Reset), PTC(Thermistor input), STA(3-wire start), STP(3-wire stop), F/R(3-wire fwd./rev.), PID(PID On/Off), PIDC(PID reset), UP/DWN(Remote-controlled accel./decel.) , UDC(Remote-controlled data clearing), OPE(Operator control), ADD(ADD frequency enable), F-TM(force terminal mode), RDY(quick start enable),S-ST(Special-Set 2nd Motor Data),EMR, NO(Not selected) 
OutputIntelligent output terminal27V DC 50mA max open collector output, 1 terminals, 1c output 250V AC/30V DC 2.5A relay (AL0, AL1, AL2 terminals) 
FunctionsRUN(run signal), FA1(Frequency arrival type 1 - constant speed), FA2(Frequency arrival type 2 - over-frequency), OL(overload advance notice signal), OD(Output deviation for PID control), AL(alarm signal), DC(Wire brake detect on analog input), FBV(PID Second Stage Output), NDC(ModBus Network Detection Signal), LOG(Logic Output Function), ODC(Option Card Detection Signal), LOC(Low load) 
Analogue output terminal0 … 10 V, analogue frequency monitor, analogue current monitor 
Serial portRS485 (Modbus RTU) 
StandardsCE, UL, cUL, c-Tick 
ProtectionOvercurrent, overvoltage, undervoltage, overload, overheat, ground fault protection at startup, input overvoltage, external trip, EEPROM error, CPU error, USP error, Termistor error, Driver error, Safety stop 
Environ-mental conditionsTemperature / humidity-10 … +50 °C (carrier derating required for ambient temperature higher than 40 °C), no freezing / 20 … 90 % humidity (non condensing) 
Vibration / lnstallation5.9 m/s2 10…55 Hz / altitude 1000 m or less, indoors, no corrosive gases or dust 
OptionsRemote operator, copy unit, cable for digital operator, reactor for improving power factor, noise filter, ProDrive Software 
Protection classIP20 
Weight kg (approx.)0.81.01.52.42.51.52.3 
 80 x 155 x 9380 x 155 x 107110 x 189 x 128110 x 189 x 155
 
 
X2003-phase 400 V class
Model number004 HFEF007 HFEF015 HFEF022 HFEF030 HFEF040 HFEF055 HFEF075 HFEF
Applicable motor (kW)0.40.71.52.23.04.05.57.5
Rated output current (A)1.52.53.85.57.88.61316
Rated input voltage3 ~ 380 … 480 V, +10 %, -15 %, 50/60 Hz ±5 %
Rated output voltage3 ~ 380 … 480 V (corresponding to input voltage)
Integrated EMC filterEN61800-3 category C2 filter
Output frequency range0.5 … 400 Hz
Frequency accuracy (at 25 °C ±10 °C)Analogue setting: ±0.4 %, digital setting: ±0.01 %
Frequency setting resolutionAnalogue setting: Maximum frequency/1000, digital setting: 0.1 Hz
V/f characteristicsV/f control, V/f variable (constant torque, reduced torque)
Overload capacity150 % for 60 s
Acceleration/deceleration time0.01 - 3000 s (linear, sigmoid), two stage accel./decel.
Starting torque100 % at 6 Hz
InputIntelligent input terminal10 kOhm input impedance, sink / source logic selectable
FunctionsFW(Forward), RV(Reverse), CF1-CF4(Multispeed command), JG(Jogging), DB(External DC braking), SET(Second motor constants setting), 2CH(Second accel./decel.), FRS(Free-run stop), EXT(External trip), USP(Unattended start protection), SFT(Software lock), AT(Analog input selection), RS(Reset), PTC(Thermistor input), STA(3-wire start), STP(3-wire stop), F/R(3-wire fwd./rev.), PID(PID On/Off), PIDC(PID reset), UP/DWN(Remote-controlled accel./decel.) , UDC(Remote-controlled data clearing), OPE(Operator control), ADD(ADD frequency enable), F-TM(force terminal mode), RDY(quick start enable),S-ST(Special-Set 2nd Motor Data),EMR(Safety stop), NO(Not selected)
OutputIntelligent output terminal27V DC 50mA max open collector output, 1 terminals, 1c output 250V AC/30V DC 2.5A relay (AL0, AL1, AL2 terminals)
FunctionsRUN(run signal), FA1(Frequency arrival type 1 - constant speed), FA2(Frequency arrival type 2 - over-frequency), OL(overload advance notice signal), OD(Output deviation for PID control), AL(alarm signal), DC(Wire brake detect on analog input), FBV(PID Second Stage Output), NDC(ModBus Network Detection Signal), LOG(Logic Output Function), ODC(Option Card Detection Signal), LOC(Low load)
Analogue output terminal0 … 10 V, analogue frequency monitor, analogue current monitor
Serial portRS485 (Modbus RTU)
StandardsCE, UL, cUL, c-Tick
ProtectionOvercurrent, overvoltage, undervoltage, overload, overheat, ground fault protection at startup, input overvoltage, external trip, EEPROM error, CPU error, USP error, Termistor error, Driver error, Safety stop
Environ-mental conditionsTemperature / humidity-10 … +50 °C (carrier derating required for ambient temperature higher than 40 °C), no freezing / 20 … 90 % humidity (non condensing)
Vibration / lnstallation5.9 m/s2 10…55 Hz / altitude 1000 m or less, indoors, no corrosive gases or dust
OptionsRemote operator, copy unit, cable for digital operator, reactor for improving power factor, noise filter, ProDrive Software
Protection classIP20
Weight kg (approx.)1.52.32.45.55.7
Dimensions W/H/D in mm110 x 189 x 128110 x 189 x 155180 x 250 x 163
          * Item specifications are preliminary and are subject to change without notice   
 